Arnold well owners often notice a problem before they know its cause. The pump starts and stops more often than it used to, faucets sputter when they open, or the pressure gauge seems to swing too quickly. A common source is the pressure tank itself, specifically the air charge on the far side of the bladder or diaphragm. Checking that air charge is a simple first step, and it can keep you from replacing a pump that is working correctly.
What the pressure tank does
A pressure tank stores a cushion of water under pressure so the pump does not have to run every time someone turns on a tap. Inside most tanks is a rubber bladder or diaphragm. Water fills one side, and compressed air sits on the other. When the air pressure and water pressure are in balance, the system works as designed. If the air side loses its charge, the tank holds less usable water, and the pump starts far more often.
Signs the air charge may be off
- The pump turns on and off in quick succession even when only a little water is used.
- Faucets spit or surge, and the flow feels uneven when the pump starts.
- Water sputters from taps for a moment after the pump shuts off.
- The pressure gauge needle drops quickly when a faucet opens, with little water coming out.
These signs have several possible causes, including a failing bladder, a sticking pressure switch, or a leak somewhere in the system. Air charge is one of the first things to check because it can be tested without special parts.
Before you start
Safety comes first. Shut off the breaker that feeds the well pump, not just a switch near the tank, and make sure no one is running water in the house. Keep in mind that this check only addresses the tank. It does not tell you anything about what is in the water, so water testing stays on its own track.
How to check the air charge
- Turn off the breaker for the well pump and confirm that the pump is not running.
- Open a faucet near the tank and let water run until the flow stops. This brings the water side of the tank down to zero pressure.
- Remove the cap from the air valve on the top of the tank. It looks like a tire valve.
- Attach a tire pressure gauge to the air valve and read the air pressure.
- Compare the reading to the pre-charge setting printed on the tank label, which should sit a little below the pressure at which the pump starts.
- If the reading is low, add air with a small compressor or hand pump until it matches the setting, then replace the cap.
- Close the faucet, turn the breaker back on, and watch how the pump cycles over the next several days.
When the tank needs a closer look
If the pump cycles normally after you add air, the charge was probably just low. If the air leaks out again quickly, or if water comes out of the air valve when you check it, the bladder may have failed. A ruptured bladder means the tank needs repair or replacement. That work belongs with a licensed well contractor or plumber who knows your pump system, especially if the tank or pressure switch shows other wear.
Keep the tank check and the water test separate
Checking the tank tells you about the equipment, not the water. Well owners in Arnold should also think about water testing on its own schedule. Owners in the south and west part of Jefferson County should consider lead sampling tied to the SW Jefferson County Mining Superfund area. Other owners may want to test for coliform bacteria, nitrates, or hydrogen sulfide depending on how old the well is, how deep it is, and what is nearby, such as a septic system or farm fields.
Keep a simple record
Write down the date, the air reading, and any change in how the pump behaves. A written record helps you spot a slow loss of air over time, and it gives any technician who visits useful history about the system. Pair these notes with your water test results so you have one place to look when something changes.